Details: |
Heavy Duty Series
- Designed for powering 12 VDC communication/navigation equipment
aboard commercial vessels where reliability is the primary consideration.
- Input voltage 115 or 230 VAC selected by slide switch on the front
panel.
- Excellent Regulation and Ripple Spec: Output voltage maintained within
1% under all line and load conditions within rating; Ripple is less than 40
mV P-P. (12 volt) or 70 mV P-P (24-volt)
- Polyurethane conformal coated PC board and corrosion resistant heavy
duty aluminum case with integral shock mounts assures survival in hostile environments
- Heat generated by semi-conductors is extracted and dissipated by large
heat sink fins that maximize air contact for cool operation and long life of
components.
- Supply and Load Circuit Protection: over voltage, current limit; (set @
105% of intermittent rating), thermal overload and input/output fusing.
- Thermally activated cooling fan on “CD” units.
Nominal |
Output
Amperage |
Case Size
(P-3) Inches |
Weight |
Input |
VAC |
Intermittent |
Continuous |
H |
W |
D |
Lbs. |
115 |
230 |
20 |
8 |
5.7 |
4.8 |
16.3 |
20 |
Output Voltage
12 V Models:
13.6 VDC (Internally adjustable 12.6-14.5 VDC)
Ripple: 40mV P-P ( @ 110-125 / 220-250 VAC input)
Input Range
105-125/210-250 VAC (selectable), 50-60 Hz
Derate to 50% output below 110 and 220 VAC
Operating Temperature
Standard Units
0-50°C, Derate Linearly From 100% @ 40°C
To 50% @ 50°C Thermal shutdown @ 85°C Case temperature
C.D. Units
0-65°C, Derate Linearly From 100% @ 50°C
To 50% @ 65°C Thermal Shutdown @ 85°C Case temperature
Duty Cycle
Intermittent: 20 minutes max on time, 20% duty
Continuous: 24 Hours/Day 100% Duty
Options
- Use as a Battery Charger
- Output voltage adjust (see Output Voltage for range)
- Transfer relay for back up battery in event of power failure (ERC
option)
|
|
Did you Know?
ALL products we sell are factory new and come with the full Manufacturers Warranty! |
|
|