Includes the features of the M-2A: - microprocessor-controlled
- low profile, water resistant design
- two-channel monitoring capability
- plug-in sensors (second sensor optional)
- fault light alarm
- fault lights to indicate a malfunction in either the module or one of the sensors
- "press to test" button for each channel indicates either an OK or Danger condition
- Alarm Silence button deactivates the alarm horn
- calibrated to eliminate most nuisance alarms while allowing enough time to take action
The MB-2 adds automatic bilge blower control. The blower is automatically started when a fume level of 16 to 20% LEL (lower explosive limit) is reached and remains on until fume level is safely lowered. A 30 amp relay is standard. The MB-2 system also includes a test button at the display module to activate the warning lamp, alarm horn and blower motor.
|